Whirlpool WGDH160UH User Manual

Page of 16
6
Install Dehumidifier—Existing Furnace or Air Handler
NOTE: When using the existing duct system, the dehumidifier fan 
and the existing system fan must be interlocked by using the low 
voltage interlock method provided with the dehumidifier. See the 
wiring diagrams in the “Electrical Connections” section. 
1. Disconnect power.
2. Place the dehumidifier in final location. See “Location 
Requirements.”
3. Attach 
³⁄₄" PVC pipe to the condensate drain outlet. See 
“Location Requirements.”
4. Run the PVC pipe to an outdoor drain. Any horizontal run of 
drain pipe must have an anti-siphon vent for it to drain 
properly.
5. If needed, install a condensate pump kit (optional).
6. Using a 10" duct, attach the discharge air supply on the 
dehumidifier to the return air supply on the existing furnace or 
air handler. 
NOTE: Install ductwork in accordance with NFPA 90B 
Standard for the Installation of Warm Air Heating and Air 
Conditioning Systems (latest edition) and any local codes.
7. Attach the return air supply on the dehumidifier to the return 
air supply on the existing furnace or air handler near the 
return air grille.
NOTE: Do not draw air directly from the kitchen, bathroom, 
laundry room or unconditioned isolated basement.
Horizontal Installation
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
dehumidifier.
Failure to do so can result in back or other injury.
A. Return air from house
B. Existing return air duct
C. Dehumidifier
D. To existing furnace or air handler
C
B
D
A