Vertical Installation
Install Dehumidifier—Existing Furnace or Air Handler with Fresh Air Duct
NOTE: Locate the outside air intake away from undesirable 
fumes, gases or odors.
Advantages of fresh air ventilation:
Outside air is filtered before entering the building.
Outside air will be dehumidified by the dehumidifier before 
entering the building.
Outside air entering the building through the dehumidifier 
helps equalize pressure to prevent humid air from entering 
the building through other means.
In cold climates, outside air can have a lower dew point and 
can lower humidity inside the building without running the 
dehumidifier.
NOTE: When using the existing duct system, the dehumidifier fan 
and the existing system fan must be interlocked by using the low 
voltage interlock method provided with the dehumidifier. See the 
wiring diagrams in the “Electrical Connections” section. 
1. Disconnect power.
2. Place the dehumidifier in final location. See “Location 
Requirements.”
3. Attach 
³⁄₄" PVC pipe to the condensate drain outlet. See 
“Location Requirements.”
4. Run the PVC pipe to an outdoor drain. Any horizontal run of 
drain pipe must have an anti-siphon vent for it to drain 
properly.
5. If needed, install a condensate pump kit (optional).
6. Using a 10" duct, attach the discharge air supply on the 
dehumidifier to the return air supply on the existing furnace or 
air handler. 
NOTE: Install ductwork in accordance with NFPA 90B 
Standard for the Installation of Warm Air Heating and Air 
Conditioning Systems (latest edition) and any local codes.
7. Attach the return air supply on the dehumidifier to the return 
air supply on the existing furnace or air handler near the 
return air grille.
NOTE: Do not draw air directly from the kitchen, bathroom, 
laundry room or unconditioned isolated basement.
8. Using a 6" diameter insulated duct, attach to the return 
plenum on the dehumidifier. 
9. Install the outside air intake in a location away from 
undesirable fumes, gases and odors.
10. Install a screened intake hood on the outside air intake duct. 
Be sure screen is clear of debris at all times to ensure proper 
air flow to dehumidifier.
11. Install a manual damper on the return air side of the 
dehumidifier. 
NOTE: If desired, a power damper may be installed.
A. Return air from house
B. Existing return air duct
C. Dehumidifier
D. To existing furnace or air handler
A
B
C
D
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
dehumidifier.
Failure to do so can result in back or other injury.