Troubleshooting 
Page 6-11
Call to Non-Local Extension: Warble Tone (Error Tone) 
6
If FRL settings are not the cause, go to Possible Cause 9.
Possible Cause 9: If the call is a 64-kbps data call, all routing facilities may not 
support this data speed.
What to Do: Unless you are directly connected to the destination system, the 
coordinating system manager must check the routes for the call. To check the 
local routes, se
. To 
change the routing in order to specify facilities that can handle the call, see 
 or “UDP Routing” in Chapter 4 of 
System 
Programming. 
If the call is routed over any analog facilities (tie or loop-start, for example), or 
T1-emulated voice or data facilities, it cannot go through because they support 
less than 64 kbps. If the call is routed over PRI and/or BRI facilities, a speed of 64 
kbps may be possible. If this is not the cause of the problem, call the Lucent 
Technologies Helpline at 1 800 628-2888; consultation charges may apply.
Call to Non-Local 
Extension: Warble Tone (Error Tone)
6
There are several reasons why a call to a non-local extension receives warble 
tone. The first two possibilities are easy to check, because they all derive from the 
local system. The third possible cause only occurs when there are tandem PRI 
facilities included in the route for the call.
Possible Cause 1: The extension number is omitted from the non-local dial plan. 
What to do: Check your system’s non-local dial plan to see whether the 
destination extension number is included in a programmed extension range. If it is 
not, you have solved the problem. If it is included, check all tandem switches to 
ensure that the extension is in their non-local dial plans. To add the extension to 
the non-local dial plan, consult the coordinating system manager and see 
 or “System Renumbering” in Chapter 3 of 
System Programming. If it is included in all programmed extension ranges, 
proceed to Possible Cause 2.
Possible Cause 2: The remote system rejects the dialed number on an all PRI 
private network route. 
What to do:
 Check that the number that arrived is in the non-local dial plan. If the 
number is in the non-local dial plan, verify that it is a valid extension number for a 
station, adjunct, calling group, Listed Directory Number (LDN), Remote Access, 
Dial 0, or ARS.