Troubleshooting 
Page 6-21
Network Call Transmission Level (Volume) Too Low or Too High 
6
2.
As necessary, note the switch identifier programmed on each system for 
the trunks that carry the calls. To review a report including the switch 
identifiers programmed on a system, select the 
3ULQW
 option on the System 
Programming menu and then choose
7UXQN,QIR
and
*HQHUDO
3.
Look for switch identifiers that incorrectly specify the distance between 
systems or that specify the incorrect type of system. The diagram below 
shows how switch identifiers might be programmed at either end of tandem 
trunks in a hypothetical private network. A switch identifier is programmed 
to identify the system at the 
opposite end of the tandem trunk. In the 
example, all three switches are MERLIN LEGEND Communications 
Systems. On the facility that links Systems A and B, the system managers 
program identifiers to indicate that they are within 200 miles of one another. 
Next to the name of each system, is the switch identifier associated with 
that switch. The switch is programmed on the switches on the other end of 
the tandem trunk. Systems B and C are linked by trunks whose identifiers 
indicate distant systems.
The example below shows programming that would be incorrect in the 
same private network. The link between Systems A and B has mismatched 
identifiers, because System B specifies that System A is more than 200 
miles away. System C incorrectly specifies System B as a non-MERLIN 
LEGEND Communications System. 
4.
If any of the programming is incorrect, one or more system managers must 
correct it. The coordinating system manager must clear any changes. To 
change the switch identifiers at your local system, see 
on page 19
 or “UDP Facilities” in Chapter 4 of 
System Programming. If the 
programming appears to be correct, skip to Step 6.
5.
Make some test calls across the private network. If calls are at the proper 
levels, the problem is solved. If transmission levels are still incorrect, 
proceed to Step 6.
6.
If the identifiers appear correct but the distance between systems is 
between 180 and 220 miles, you may need to experiment with switch 
identifiers in order to achieve the correct transmission levels. Return to 
Step 4.
If changing one or more switch identifiers do not solve the problem, 
System A
System C
System B
21
22
02
03
NY, NY
Queens, NY
Atlanta, GA
tandem
trunk
tandem
trunk
System A
System C
System B
01
21
42
03
NY, NY
Queens, NY
Atlanta, GA
tandem
trunk
tandem
trunk
X
X