Troubleshooting 
Page 6-29
Calls From a Remote System to Centralized Voice Messaging System Get the 
6
instructions for determining the switch type programmed at your system 
and changing it if necessary. “Switch Type” in the Chapter 4 “PRI Facilities” 
section of 
System Programming gives full details.
In Release 6.1 and later systems, the PRI Switch Type Test requests the 
system at the other end to respond with information about the system 
mode specification. Lucent Technologies technicians or authorized 
representatives can run this test to determine the mode of the system at 
the other end.
If the call is carried over other systems connected by tandem PRI facilities, 
the coordinating system manger must ensure that the settings are correct, 
as in this example of MERLIN LEGEND Communications Systems:
System A LEGEND-PBX
System B LEGEND-Ntwk
System C LEGEND-PBX
If the switch type settings are correct and problem persists, call the Lucent 
Technologies Helpline at 1 800 628-2888; consultation charges may apply.
Calls From a Remote System to
Centralized Voice Messaging System
Get the Wrong Message or Go To 
Operator
6
The following are likely circumstances in which calls reach the centralized voice 
messaging system but receive the wrong message, for example, automated 
attendant instead of voice mail, or no message, or go to operator: 
Possible Cause 1: There may be a numbering conflict in the switch identifiers for 
the trunks that carry the call. Within a private network, switch identifiers should be 
unique and unambiguous. If they are not, calls may terminate prematurely or 
continue to route unexpectedly.
What to Do: Dial the local VMI group. If the problem still occurs, the coordinating 
system manager must check system planning Form Non-Local UDP 
Administration Form in the Installation Specification and review the switch 
identifiers for all systems over which calls travel to reach the destination 
extension(s). To review a report including the switch identifiers programmed on 
your local system, select the 
3ULQW
 option on the System Programming menu and 
then choose
7UXQN,QIR
and
*HQHUDO
.
If the switch identifiers are missing or not correct, the coordinating system 
manager must see that a change is made at one or more non-local 
systems where the conflict exists. To change the current switch identifiers 
at your local system, se
 or “UDP Facilities” 
in Chapter 4 of 
System Programming.