Lucent Technologies 555-661-150 User Manual

Page of 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Troubleshooting 
Page 6-30
No Message Waiting Light Update 
6
If the switch identifiers are correct and the problem persists, do one of the 
following:
— If the call is being routed over any tandem PRI facilities, go to Possible 
Cause 2. 
— If the call is being routed over tandem tie trunks, the call information sent 
to the centralized VMS/AA for both inside calls and outside calls 
indicates an outside calls.
Possible Cause 2: System programming is not correct or tandem tie trunks are 
used to route the call.
What to Do: The action you takes depends on how frequently the problem 
occurs:
If the problem occurs for all calls, verify that the outgoing VMI calling group 
is programmed as Integrated VMI.
If the problem occurs only on tandem tie-trunks, verify trunk type. The call 
information sent to the VMS for both Inside calls and outside calls indicates 
an inside call. Program the VMS message as necessary to provide a 
generic message for both inside and outside calls.
If the problem occurs only on tandem PRI trunks, Verify that switch 
identifier is not zero. See procedure earlier in this chapter.
If the problem occurs only at certain times, check the time zone for Night 
Service and make adjustments to VMS recordings as needed.
No Message Waiting Light Update
6
The following are likely circumstances in which Message Waiting lights are not 
updated: 
The error log indicates that Message Waiting light update has been 
delayed more than one minute. Errors are 0C04 (Message Waiting light 
facility timeout) and 0C05 (Message Waiting light delivery delay).
A selected tandem facility between the caller or called VMI extension is out 
of service. Check the error logs and if the error indicates an out of service 
condition, call the Lucent Technologies Helpline at 1 800 628-2888; 
consultation charges may apply.
No Touch-Tone Receivers (TTRs) available at a remote system when using 
tie trunks. This can be verified by checking for the 0c03 error on the error 
log on the remote switches. If this error persists, contact your local service 
representative.
A technician may be performing maintenance on local tandem trunks or 
non-local tandem trunks included in the routes for the call.
A power failure may have occurred at the destination system or at another 
networked system whose tandem trunks are included in routes for the call.