Lucent Technologies 555-661-150 User Manual

Page of 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Troubleshooting 
Page 6-32
No Message Waiting Light Update 
6
If more trunks are available and need to be assigned, follow the procedure 
in “Trunks to Pools Assignment” in Chapter 4 of 
System Programming to 
assign more tandem trunks. All the tandem trunks in a pool must be of the 
same type (tie or PRI). 
If not enough trunks are available, consider adding more to your system. 
If there are sufficient trunks assigned but the problem persists, go to 
Possible Cause 4.
Possible Cause 4: No Touch-Tone Receivers (TTRs) available at the hub or at a 
remote system when using tie trunks to send message waiting light updates.
What to Do: This can be verified by checking for the 0c03 error on the error log 
on the hub and on the remote switches. If this error persists on any switches in the 
private network, contact your local service representative.