Lucent Technologies 555-661-150 User Manual

Page of 360
MERLIN LEGEND Communications System Release 6.1
Network Reference  
555-661-150  
Issue 1
August 1998
Voice/Fax Messaging Systems 
Page C-2
Supported System Considerations 
C
Supported System Considerations
3
The following are considerations for voice messaging systems used for 
centralized automated attendant on MERLIN LEGEND Communications System 
Release 6.0 Version 11 and later systems.
MERLIN LEGEND System
3
For Release 6.1 and later systems, the number of dialed digits for the non-local 
UDP range for a given pattern must be entered in a new system programming 
screen (14.515). To access this screen, select 
6\V5HQXPEHU
.
1RQ/RFDO8'3
.
Enter 
first extension number in range
.
;.
Enter last extension number in 
range
.
;.
Enter number of dialed digits for the range
.
;
.
Intuity AUDIX
3
All local and non-local UDP stations must be administered on Intuity 
AUDIX. 
Within Intuity AUDIX, the parameter “transfer to subscribers only” must be 
administered so as to ensure that Intuity AUDIX will deny transfers to all 
but local and non-local UDP stations.
When optioned for MERLIN LEGEND systems, Intuity AUDIX can handle 
3- or 4-digit dial plans (but not both simultaneously). For example, you 
cannot have a 3-digit dial plan for one site and a 4-digit dial plan at another 
site. Note that since a 5-digit dial plan is not supported by Intuity AUDIX 
when optioned for MERLIN LEGEND systems, one of the work-arounds 
described in Chapter 5 must be used to route calls to DEFINITY ECS or 
DEFINITY ProLogix or the DEFINITY must have a 4-digit dial plan.
The MAP/5P platform supports 500 subscribers, the MAP/40 supports 
3000 subscribers, and the MAP/100 supports 6000 subscribers.
Beginning with Intuity AUDIX R4, enhanced transfer security is available by 
administering the allowed numbers list. Unless an extension (local and 
non-local UDP) appears in this list, calls will not be transferred to that 
number.
MERLIN LEGEND Mail
3
MERLIN LEGEND Mail should be set up with “Transfer to Subscriber-Only 
Restrictions.” 
For local UDP extensions, call answer mailboxes (up to 100) should be 
used. 
For non-local UDP numbers, transfer-only mailboxes should be used. The 
maximum number of mailboxes of both types is 375.