Installing the Control Unit 
Page 2-17
Unit Loads 
Unit Loads
A unit load is a measure of power (1.9 watts) that you use to determine 
the electrical load that the components listed below place on the control 
unit’s power supply.
Telephones and adjuncts
800 DID modules
Only the telephones and adjuncts that connect to the analog and digital 
extension jacks (ports) on the control unit require unit load calculation. 
When calculating unit load, do not include any equipment with its own 
power supply.
Checking Unit Loads
In the event of maintenance or equipment changes, recalculate the unit 
loads for each carrier where there is a new configuration. Use the 
worksheet in Appendix B, “Unit Load Calculation Worksheet.”
As a general rule, if you can distribute the 800 DID modules and 
telephone modules equally across the carriers, you prevent 
unnecessary drain on any one carrier. However, the rule varies 
depending on the system’s operating mode. The next two sections 
provide the rules for calculating unit loads in various modes.
Unit Loads for Hybrid/PBX Mode
Older power supplies (models 391A1 or 391A2) generally support six 
modules of any type in Hybrid/PBX mode, without requiring an upgrade 
to a newer power supply (model 391A3 or 391C1). If the following 
conditions are true, however, the unit loads on a carrier can exceed the 
54-unit maximum and, therefore, require a newer power supply (model 
391A3 or 391C1):
All six carrier slots are occupied by MLX telephone or analog 
multiline telephone modules.