Lucent Technologies 4.1 User Manual

Page of 363
Problems with Auxiliary Equipment
Standard Device Does Not Answer
Possible Cause: A standard device (such as a fax machine or answering machine) does
not answer intercom calls or transferred calls because it does not recognize the distinctive
ringing pattern used by the system.
What to do: Change the extension’s setting for Distinctive Ring (#308) to Not Active, so
the extension uses the same ringing for intercom and transferred calls as it does for
outside calls.
If the device works properly, the problem is solved.
If the problem remains, call the hotline.*
Standard Device Does Not Dial Out Properly
Possible Cause: A standard device with autodialing (such as a modem) does not
recognize the intercom dial tone generated by the system.
What to do: Change the setting for Intercom Dial Tone (#309) for the extension to
Machine, so the system generates outside line dial tone for the extension.
If the device works properly, the problem is solved.
If the problem remains, call the hotline.*
Poor Transmission Quality on Modem
Possible Cause: A high-speed modem is connected through an extension jack on the
control unit to a standard central office telephone line; but the line quality is not sufficient to
generate a clear signal when the modem transmits through the system interface.
What to do: Either connect the modem directly to the network interface jack for a line, or
contact your local telephone company for information about upgrading the line quality.
If the device works properly, the problem is solved.
If the problem remains, call the hotline.*
Call Records Wrap on SMDR Printout
Possible Cause: SMDR Talk Time (#611) is set to Active and SMDR Output Format
(#610) 
is set to 24 digits, causing the combined length of the fields for a call record to be
greater than the 80 characters supported by your printer.
What to do: Reduce the font size or increase the characters-per-inch setting for the printer.
If the call records print without wrapping to the next line, the problem is solved.
If the problem remains, change the output format back to 15 digits.
In the continental U.S., help is available at 1 800 628-2888. Outside the continental U.S., call your
Lucent Technologies Representative or local Authorized Dealer.
6-14     
Troubleshooting