Chapter 2: Diagnostics and Configuration
 17
Revision D 12/09
A799-PG00001D
Communication interface
To change the communication interface settings, enter the configuration menu, select “Set Communication Interface” from 
the main menu and answer “Yes” to “SET INTERFACE TYPE?” printed on the receipt.
Caution:  Be extremely careful changing any of the printer settings to avoid inadvertently changing other settings that 
might affect the performance of the printer.
Press the paper feed button as instructed to select the communication interface you want.
•  Communication interface
•  RS-232C interface:  1 click
•  USB: 
 
Auto when no RS-232C activity
RS-232C serial interface settings
To change the RS-232C serial interface settings, enter the configuration menu, select “Set Communication Interface” 
from the main menu and answer “No” to “SET INTERFACE TYPE?” printed on the receipt. This will take you to the 
instructions for selecting the RS-232C settings.
Caution:  Be extremely careful changing any of the printer settings to avoid inadvertently changing other settings that 
might affect the performance of the printer.
Press the paper feed button as instructed on the configuration menu to select the RS-232C settings you want to change.
•  Baud rate
    115200 baud
    57600 baud
    38400 baud
    19200 baud
    9600 baud
    4800 baud
    2400 baud
    1200 baud
•  Number of data bits (can not be changed)
•  Stop bits (can not be changed)
•  Parity (can not be changed)
•  Hardware flow control
    Software (XON/XOFF)
    Hardware (DTR/DSR)
•  Data reception errors
    Ignore errors
    Print “?”
•  Alternate DTR/DSR
   
Enabled
   
Disabled
Note:  Press the paper feed button for at least one   
 
  second to validate the selection.
For more information about  See this section
Setting the RS-232C Serial  
“Configuring the printer” 
interface settings 
on page 16