3.2  Burner and Nozzle Data Tables 
 
 
Burner
 
Nominal 
heat 
capacity 
(kW)
 
 
Bottled gas – G30/G31  30/37 mbar
 
 
 
Nozzle 
diameter 
1/100 mm
 
By-pass 
mm 
1/100 
Reduced 
heat 
capacity 
(W)
 
Flow rate 
g/h G30
 
Flow rate 
g/h G31
 
Auxiliary
 
1.05 
50 
30 
400 
76 
75 
Semi rapid
 
1.8 
65 
33 
500 
131 
129 
Rapid
 
85 
45 
800 
218 
215 
Ultra rapid
 
4.0 
100 
65 
1600 
290 
286 
 
 
 