Smeg A2PY-6 Manual De Usuario

Descargar
Página de 38
 
 
Instructions for the Installer
 
 
50
 
4.  FINAL OPERATIONS 
After changing the nozzles, put the pan stands, the burner caps and 
flame diffuser rings back in place. 
 
 
 
 
After adjusting for use of a gas other than the gas used for testing the 
appliance, replace the gas setting label inside the storage compartment 
with the label for the new gas. The label is available from your nearest 
Authorised Service Centre. 
 
4.1  Adjusting the minimum setting for town gas and natural 
gas 
Light the burner and turn it to the minimum setting 
. Remove the gas tap knob and adjust the 
regulator screw inside or beside the tap rod 
(depending on the model) until an even minimum 
flame is obtained. Put the knob back in place and 
check the stability of the burner flame (the flame 
must not go out when the knob is turned quickly 
from the maximum to the minimum setting). Repeat 
the operation on all the gas taps. 
 
4.2  Adjusting the minimum for bottled gas 
The diameters of the bypasses for each individual burner are stated in 
point "3.2 Burner and nozzle characteristics table". When the adjustment 
is complete, re-seal the bypasses with paint or another similar material. 
 
 
4.3  Positioning and levelling the appliance 
 
After making the electrical and gas connections, level the appliance by 
means of its four adjustable feet.