Bk Precision BK-2831E Digital-Multimeter, DMM, VFD 20000 counts CAT II 300 V BK-2831E Hoja De Datos

Los códigos de productos
BK-2831E
Descargar
Página de 78
18 
 
Chapter 3    Basic Measurements 
3.1    Preparation 
One of the first things you would like to do with your multimeter is to become acquainted with its front 
panel. We have provided some exercises in foregoing chapters about preparations for use and 
operations of front panel.   
 
The front panel has six rows of keys to select various functions and operations. Most keys have a shifted 
function printed in blue above the key. To perform a shifted function, press 
  (the Shift annunciator 
will turn on). Then, press the key that has the desired label above it.  For example, to select the AC 
current function, press 
  then press        (ACI). 
 
If you accidentally press
, just press it again to turn off the Shift annunciator. 
3.2    Measuring Voltage   
Voltage ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V (750 VAC) (model 5491B: 500 mV, 5 V, 50 V, 500 V, 
1000 V (750 VAC)) 
Maximum resolution: 50 
μV for DC and 1 mV for AC (on 200 mV range (model 2831E) and on 500 mV 
range (model 5491B)) 
AC technique: true RMS, AC-coupled, 1000 V Peak AC 
 
3.2.1    Connections 
Assuming the multimeter is under factory default conditions, the basic procedure is as follows: 
1.  Connect test leads to 
  and COM terminals. 
2.  Select DC or AC voltage measurement by pressing 
  or       . 
3.  Press 
  to toggle  between  auto  and manual  ranging. Notice  that  the  AUTO  annunciator is 
displayed  when in auto ranging  mode. If you want manual ranging, use the RANGE 
  and 
  keys to select a measurement range consistent with expected voltage. 
4.  Connect test leads to the sources as shown in Figure 3-1. 
 
CAUTION:   Do not apply more than 1000V peak
 
to the input or instrument damages may occur.   
 
5.  In manual range, if the “OVL.D” message is displayed, press the up 
  key to select a higher 
range until a desired  reading is displayed (or press 
  key for auto ranging). Use the lowest 
possible range for the best resolution.   
ACV 
DCV 
ACV