Wr Rademacher DuoFern 14234511 Wireless blind cord winder Flush mount 14234511 Hoja De Datos

Los códigos de productos
14234511
Descargar
Página de 44
20
EN
i
Set the upper end point
1. 
  +  
 
Simultaneously press and hold the 
 
buttons.
The roller shutters travel up.
NOTE
Tighten the belt slightly, until it is ten-
sioned by the weight of the roller shutters.
2. 
 
  +  
 
Release the buttons... 
...as soon as the roller shutter achieves the 
desired position for the upper end point. 
The roller shutter stops and the upper end 
point is stored. 
IMPORTANT
Do not set the upper end point right up to the limit stop. 
Release the key promptly and never allow it to extend 
beyond  the  respective  end  point.  Failure  to  do  so  can 
cause overloading and may damage the roller shutters 
and/or drive.
13.  End point adjustment
IMPORTANT
The end points must be configured in order that the roller shutters stop at the desired upper and lower positions. It is imperative that 
both end points are configured, otherwise malfunctions may occur.
 
If the RolloTron Standard DuoFern is operated without an end point setting, the drive will continue to run for as long as one of 
the two control keys is actuated.
 
The automatic functions remain blocked until the end point setting is configured.