25.  Removing the belt in the event of unit failure
In the event that the RolloTron Standard DuoFern unit fails 
and the motor no longer runs, you can use the disengaging 
bracket provided in order to fully remove the belt from the 
belt winder unit, without the need for cutting it.
1. 
Remove the mains plug from the socket.
2. 
Dismantle the RolloTron Standard DuoFern as previ-
ously demonstrated on page 33.
3. 
Release the drive with the help of the supplied disen-
gaging bracket.
ATTENTION
 
Hold on to the belt tightly, as otherwise the roller shut-
ters may slam shut.
 
A small amount of resistance must be overcome when 
pressing.
4. 
Maintain pressure on the disengaging bracket and pull 
the belt out of the RolloTron Standard DuoFern as far 
as possible.
5. 
Release the belt from the fastening hook and pull it 
out completely from the RolloTron Standard DuoFern.
6. 
Place the disengaging bracket back in its holder.
RolloTron 
Standard 
DuoFern
RolloTron 
Standard 
DuoFern 
Plus
i
Drive release
Storage bay
Drive release