Electronic Control System 
26
311163ZAC
Standard Operation
NOTE: When raising and lowering the ram plate, make 
sure there are no objects obstructing the unit.
Loading the Bin
1.
Open the air shutoff valves for the air controls and 
pumps.
2.
On the electronic control panel, press the RAM UP 
button. If the ram does not elevate, increase the ram 
up air regulator pressure in the pneumatic control 
panel.
3.
Move the bin in front of the frame.
4.
Remove the lid from the fluid bin to expose the fluid 
bag. If present, open the outer plastic bag and pull it 
up over the sides of the bin, exposing the aseptic 
inner bag.
5.
Secure the bag sides by using clamps (37) and 
tubes (38). See F
6.
Load the bin of material into the center of the frame.
7.
Initial Startup Only: The frame has spring-loaded 
guides to stabilize the bin. Adjust the guides equally 
with the screws on all four sides of the bin. Leave 
enough space between guides and bin to allow for 
removal of the bin.
8.
Make sure the corner seals (21) are in place.
9.
Use corners (39) to help guide the plate. See F
10. Press the RAM JOG button.
NOTE: It can take 5-15 seconds for the ram plate to 
start lowering.
11. Use the ram plate handles to center the ram plate 
inside the bin. Be careful not to pinch the inflatable 
seal when it enters the bin.
NOTE: The ram plate stops when it contacts the
material.
F
IG
. 15
TI16235a
38
37
21
39
When raising or lowering the ram plate, keep hands 
and body away from ram plate and bin lip.