Maintenance 
28
311163ZAC
Maintenance
Air Motor Icing
Air motor icing occurs when moisture in the compressed 
air collects in the air motor and freezes, causing the 
motor to stall. If icing occurs with any of the pumps, shut 
off the air supply to all pumps and allow the ice to thaw.
To minimize icing:
Reduce the moisture in your compressed air by 
using an air dryer or filter, which traps water.
Main air line should slope slightly downward so 
water collects and can be drained at the end of the 
line.
Plumb a drop line from the top of each main air line. 
Install an automatic drain or drain valve at the bot-
tom of each drop.
Ensure air motor exhaust tube is outside of a refrig-
erated area.
Preventive Maintenance
Your system operating conditions determine how often 
maintenance is required. Record when and what kind of 
maintenance is needed to create a maintenance sched-
ule.
Flushing the System
The equipment was tested with water. Flush the 
system before loading material.
Flush regularly to avoid having material dry and 
build up and possibly contaminate new material or 
cause blockages.
Flush at the lowest pressure possible. Check con-
nectors for leaks and tighten them if necessary.
To flush the system:
1.
Load a bin containing water, compatible solvent, or 
cleaning solution that can dissolve the material and 
clean the system. Follow the procedure foLoading 
the Bin
,
 page 18 or page 27.
NOTE: Use solvent that is compatible with the equip-
ment wetted parts and the material you will dispense. 
See Technical Data in your pump manual for wetted 
parts and consult your material supplier.
2.
Operate the pumps and circulate the cleaning fluid 
through the system for about 1-2 minutes or until the 
equipment is clean.
3.
Remove the bin of cleaning fluid from the frame. Fol-
low the procedure foUnloading the Bin, page 18 
or page 27.
4.
Operate the pumps at low pressure to remove 
excess solvent.
5.
Cleaning Pumps
1.
2.
Remove pumps from plate and frame.
3.
See the pump manual for maintenance and service 
procedures.
NOTICE
Operating the system without all the pumps func-
tioning can damage the system