311163ZAC
27
Automatic Evacuation of the Bin
1.
On the Operator Interface, select TARGET/ACTUAL 
RUN screen.
2.
Ram plate seal inflates.
3.
Ram down air pressure is applied and pumps start 
in slow mode, then switches to fast mode.
4.
When the low limit setting is reached, the pumps 
switch to slow mode for 2 minutes and then stop.
5.
The ram plate seal deflates and the ram is raises.
Unloading the Bin
1.
2.
Ensure seal is deflated and ram is raised.
3.
Unload the bin from the frame.
System Shutdown
Depending on the type of material, it may be best to 
deflate the seal and raise the ram plate out of the mate-
rial or keep the ram plate lowered in the bin. Some 
materials dry and harden when exposed to air. Cover 
materials when they are not being used.
Press arrow 
➜ 
to select RUN and press ENT.
TARGET 1000 LBS
RUN
ACTUAL 0000 LBS
EXIT