Adjust Packing Nuts
NOTE: There must be no pressure when adjusting the 
packing nuts. Air pressure in the feed tanks is too much.
1.
Follow Pressure Relief Procedure, page 46
including relieving air pressure in the tanks.
2.
Fill metering pump packing nuts with throat seal liq-
uid (TSL).
3.
After TSL is added, torque metering pump packing 
nuts to 50 ft-lb (67.5 N•m). Follow instructions in 
Xtreme Lowers manual 311762.
4.
Fill dosing valve packing nut with throat seal liquid 
(TSL).
5.
After TSL is added, tighten dosing valve packing 
nuts 1/4 turn after nut contacts packings; about 
145-155 in-lb (16-18 N•m). 
Filters
Once a week check, clean, and replace (if needed) the 
following filters. 
S100 and U100 Models:
Catalyst pump outlet filter comes with a 60 mesh fil-
ter. Two pack 60 mesh filter replacement kit, 
224459, is available.
P100 Models:
Catalyst pump outlet filter comes with a 30 mesh fil-
ter. Two pack 30 mesh filter replacement kit, 
224458, is available.
Seals
Once a week, check and tighten throat seals on the 
pumps and dosing valve.
Task
Schedule
Refer to specific component man-
ual for more detailed information.
As Required
Check catalyst (B) filter assembly 
to prevent crystallization.
Weekly
Verify calibration check assembly 
outlets are clear and unob-
structed.
Weekly
Check desiccant.
Weekly
Check restrictor housing and pin 
assembly to prevent crystalliza-
tion.
Weekly
U100: Check iso lube bottle for 
discoloration.
Daily
Perform Shutdown and install 
nightcap.
Daily
Adjust packing nuts.
When TSL has 
seeped through 
the packing nut
TSL