4 -  17 
4. STARTUP 
 
4.4.4 Parameter setting 
POINT 
 
The encoder cable MR-EKCBL M-L/H for the HF-MP series HF-KP series 
servo motor or the encoder cable MR-ENECBL M-H for HF-JP11K1M(4)  
15K1M(4) servo motor requires the parameter No.PC22 setting to be changed 
depending on its length. Check whether the parameter is set correctly. If it is not 
set correctly, the encoder error 1 (At power on) (AL.16) will occur at power-on. 
 
 
Servo motor 
Encoder cable 
Parameter No.PC22 setting 
 
 
HF-MP series HF-KP series 
MR-EKCBL20M-L/H 0
(initial value) 
 
 MR-EKCBL30M-L/H 
 
 
 MR-EKCBL40M-H 
1
 
 
 MR-EKCBL50M-H 
 
 
  
MR-ENECBL2M-H 
0
(initial value) 
 
  
MR-ENECBL5M-H 
 
  
MR-ENECBL10M-H 
 
 HF-JP11K1M(4) 15K1M(4) MR-ENECBL20M-H 
 
  
MR-ENECBL30M-H   
 
  
MR-ENECBL40M-H  1
 
 
  
MR-ENECBL50M-H   
 
 
 
When using this servo in the torque control mode, change the parameter No.PA01 setting to select the torque 
control mode. In the torque control mode, the servo can be used by merely changing the basic setting 
parameters (No.PA
) and extension setting parameters (No.PC
) mainly. 
As necessary, set the I/O setting parameters (No.PD
). 
 
Parameter group 
Main description 
Basic setting parameter 
(No.PA
Set the basic setting parameters first. 
In this parameter group, set the following items. 
Control mode selection (select the torque control mode) 
Regenerative option selection 
Torque limit setting 
Encoder output pulse setting 
Gain filter parameter 
(No.PB
If satisfactory operation cannot be achieved by the gain adjustment made by auto tuning, execute in-
depth gain adjustment using this parameter group. 
This parameter group must also be set when the gain changing function is used. 
Extension setting parameter 
(No.PC
In this parameter group, set the following items. 
Acceleration/deceleration time constant 
S-pattern acceleration/deceleration time constant 
Internal torque command 
Analog torque command maximum speed 
Analog torque command offset 
In addition, this parameter group must be set when analog monitor output, speed limit, etc. are used.
(Note) 
I/O setting parameter 
(No.PD
Used when changing the I/O devices of the servo amplifier. 
Note. The parameter No.PA19 setting must be changed when this parameter group is used.