Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
14 -  4 
14. ABSOLUTE POSITION DETECTION SYSTEM 
 
14.3 Battery replacement procedure 
 WARNING 
Before replacement a battery, turn off the main circuit power and wait for 15 
minutes or longer (20 minutes for 30kW or higher) until the charge lamp turns off. 
Then, check the voltage between P( ) and N( ) with a voltage tester or others. 
Otherwise, an electric shock may occur. In addition, always confirm from the front 
of the servo amplifier whether the charge lamp is off or not. 
 
 
POINT 
 
The internal circuits of the servo amplifier may be damaged by static electricity. 
Always take the following precautions. 
Ground human body and work bench. 
Do not touch the conductive areas, such as connector pins and electrical parts, 
directly by hand. 
 
 
14.3.1 When replacing battery with the control circuit power ON 
POINT 
 
Replacing battery with the control circuit power OFF will erase the absolute 
position data. 
 
 
Replacing battery with the control circuit power ON will not erase the absolute position data. Refer to section 
14.4 for installation procedure of battery to the servo amplifier. To replace battery with the control circuit power 
OFF, refer to section 14.3.2. 
 
14.3.2 When replacing battery with the control circuit power OFF 
Replacing battery with the control circuit power OFF will erase the absolute position data, but battery can be 
replaced without erasing the absolute position data in the following procedure. In this procedure, MR-
J3BTCBL03M battery connection cable is required. MR-J3BTCBL03M cannot be added after home position is 
set. Make sure to connect MR-J3BTCBL03M between the servo amplifier and the encoder cable when setting 
up the encoder cable. Refer to section 14.5 for the replacement procedure of the battery. 
(Note)
MR-J3BTCBL03M
Encoder cable
Servo motor
MR-J3BAT
CN4
CN2
Servo amplifier
 
Note. Make sure to install MR-J3BTCBL03M when setting up the encoder cable.