14. ABSOLUTE POSITION DETECTION SYSTEM 
 
14.5.2 Replacement procedure 
MR-J3BTCBL03M
CN4
CN2
Servo amplifier
New MR-J3BAT
MR-J3BAT
for backup
Old MR-J3BAT
 
Step 1 
Connect MR-J3BAT for backup to the battery connector of MR-
J3BTCBL03M. 
MR-J3BTCBL03M
CN4
CN2
Servo amplifier
New MR-J3BAT
MR-J3BAT
for backup
Old MR-J3BAT
 
Step 2 
Remove old MR-J3BAT from the servo amplifier. 
MR-J3BTCBL03M
CN4
CN2
Servo amplifier
MR-J3BAT
for backup
New MR-J3BAT
 
Step 3 
Install new MR-J3BAT to the servo amplifier. Then, connect the lead 
wire plug of new MR-J3BAT to the C4 connector of the servo 
amplifier. 
MR-J3BTCBL03M
CN4
CN2
Servo amplifier
MR-J3BAT
for backup
New MR-J3BAT
 
Step 4 
Remove the MR-J3BAT for backup from the battery connector of MR-
J3BTCBL03M, and the procedure is completed.