The general format for other asynchronous messages is: 
 
[Scanner_Addr] [Scanner_Addr_delimiter]  [DC2] 
MESSAGE
[CR]
 
 
      where DC2 is ASCII 0x12 (^R) character. 
 
• 
If you have not enabled the Scanner Address Stamping or the Scanner Address 
Delimiter, you must not specify them. In this case all messages will be implicitly 
addressed to the 'binded' Scanner of the cradle directly connected to the serial 
line. 
 
•  The Scanner can only receive messages if two-way mode is enabled. (See par. 
5.9.4, “Transmission Mode”, command is on page 159). 
 
•  Messages cannot start with '$+' because they would be interpreted as a 
configuration command. 
 
•  You can send a message to the Scanner only while it is on. This happens when 
it has sent a message to the host and the radio timeout has not yet expired. (See 
par. 5.9.1, "Radio Protocol Timeout"; command is on page 130). 
 
•  If you want to control the Scanner's beeper from the host, you will also probably 
want to disable the good transmission beep that is emitted when the code is 
received from the cradle. (See command on page 86). 
 
The message field can store plain text and escape sequences. 
 
• 
Escape sequences are interpreted as commands. 
 
•  Plain text is directly printed on the display. If writing beyond the end of line, the 
display does not wrap automatically. Extra characters are ignored. Control 
characters are not interpreted (i.e. LF, FF, etc.). 
 
6.1.1 
Cursor Control 
 
ESC [ 
Up 
n
 rows, no scroll 
ESC [ 
Down 
n
 rows, no scroll 
ESC [ 
Right 
n
 columns 
ESC [ 
Left 
n
 columns 
ESC [ G 
CR 
ESC [ 
Move to row 
r
, column 
c
 
(ESC[1;1H is the upper left character position of the display) 
ESC D 
Down 1 row, with scroll 
ESC E 
CR and cursor down 1 row with scroll 
ESC M 
Up 1 row and scroll 
 
NOTES
• 
Since CR is used as the message terminator, you must use ESC [ G or ESC E to 
print a CR.