Low Limit Load Errors: This screen lets you view low-load errors without 
using the control software. A low limit load error occurs if the load 
impedance falls below the value set with the Low Limit spin control on the 
Amplifi er Settings page in System Architect.
 When an error occurs, the count displayed in this screen is incremented, and 
the operating time since the error is displayed. 
To clear this screen, press and release an Encoder. The display will prompt you 
to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error reporting and set its 
limits.
High Limit Load Errors: This screen lets you view high limit load errors 
without using the control software. A high limit load error occurs if the load 
impedance rises above the value set with the High Limit  value on the 
software Control Panel.
When an error occurs, the count displayed in this screen is incre mented, and 
the operating time since the error is displayed. 
To clear this screen, press and release an Encoder. The display will prompt you 
to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error report ing and set its 
limits.
Line Voltage Errors: This screen lets you view line-voltage errors without 
using the control software. A line voltage error occurs if the line voltage falls 
outside the values set with the High/Low Limits slider on the Line Voltage 
Page of the Control Panel.
When an error occurs, the count displayed in this screen is incre mented, and 
the operating time since the error is displayed. The “Low” and “High” 
indicators show whether the line voltage was below or above the line-voltage 
limits.
To clear this screen, press and release an Encoder. The display will prompt you 
to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error report ing and set its 
limits.
Exit: To exit the Alert Menu and go to the Attenuation screen, press Menu/Exit 
once.
0
Low Limit Load Errors      
Low Limit Load Errors      
   
   
0.0 Hrs
0.0 Hrs
      
      
0.0 Hrs
0.0 Hrs
      
      
0
Last
Last
      
      
0
High Limit Load Errors      
High Limit Load Errors      
   
   
0.0 Hrs
0.0 Hrs
      
      
0.0 Hrs
0.0 Hrs
      
      
0
Last
Last
      
      
0
Line Voltage Errors      
Line Voltage Errors      
   
   
0.0 Hrs
0.0 Hrs
      
      
0.0 Hrs
0.0 Hrs
      
      
0
Last
Last
      
      
Low      L
o
w
 
 
 
 
 
 
High      H
i
g
h
 
 
 
 
 
 
Fan  Errors: When a fan error occurs, the count displayed in this screen is 
incre mented, and the operating time since the error is displayed.
0
Fan Errors      
Fan Errors      
   
   
0.0 Hrs
0.0 Hrs
      
      
Last
Last
      
      
Clear All Error Logs: In this screen, you can press and hold an Encoder knob 
to clear all the error logs.
Clear All Error Logs      
Clear All Error Logs      
   
   
Press and hold enc.      
Press and hold enc.      
to clear ALL error logs      
to clear ALL error logs      
4.2.6 NETWORKING MENU
To access this menu from the Attenuation screen, press an Encoder knob, then 
press Prev twice. This menu has screens for setting up audio network 
parameters. Push an Encoder knob to see the selections in the Networking 
Menu.
Networking Menu
Networking Menu      
Networking Menu      
   
   
Push knob for net. menu
Network Info: This screen displays information about the audio network: IP 
address, HiQnet address, Subnet and MAC address. Section 9.1 of this manual 
explains these terms.
Network Info      
Network Info      
   
   
SUBNET:255.255.0.0      
SUBNET:255.255.0.0      
MAC: 00:0A:40:00:E4:C2      
MAC: 00:0A:40:00:E4:C2      
IP:192.168.1.1        HiQNet:1      
IP:192.168.1.1        HiQNet:1      
Manufacturing Info: This screen displays information about your I-Tech HD 
amplifi er: model number, fi rmware version, serial number, and amplifi er date 
code.
Manufacturing Info      
Manufacturing Info      
   
   
S/N:8001576436      
S/N:8001576436      
Amp Mfg Date:
Amp Mfg Date:
10-9-2008
10-9-2008
IT90000HD        FW Ver:1.0.0.6      
IT90000HD        FW Ver:1.0.0.6      
HiQnet Node Address: This screen lets you set the HiQnet address of this 
amplifi er (a node in the network). Turn an Encoder knob to set the address, 
then press the knob to save your setting.
Hi
Hi
Qnet Node Addr      
net Node Addr      
   
   
Turn to Set-Press to Save
Turn to Set-Press to Save
      
      
32
4 Advanced Operation
SLM (Sweep Load Monitoring) Errors:  This screen lets you view SLM 
errors without using the control software.
When an error occurs, the count displayed in this screen is incremented, and 
the operating time since the error is displayed. 
To clear this screen, press and release an Encoder. The display will prompt you 
to confi rm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error reporting and set its 
limits.
0
SLM Errors      
SLM Errors      
   
   
0.0 Hrs
0.0 Hrs
      
      
0.0 Hrs
0.0 Hrs
      
      
0
Last
Last