Hunter Fan TYPE 2 Manuel D’Utilisation

Page de 5
REV:  5/94
FIGURE 7.
CANOPY
CEILING PLATE
MOUNTING SCREW (3)
MOUNTING SLOTS (3)
SEE FIGURE 7A.
MAKE CERTAIN GROOVE AND TAB ARE ENGAGED BEFORE RUNNING FAN.
FAILURE TO DO THIS COULD RESULT IN THE FAN FALLING.
IN CANOPY.
FOR THE HANGING FAN CONFIGURATION, ROTATE FAN UNTIL GROOVE IN BALL IS POSITIONED OVER TAB
NOTE:
--FOR HANGING FAN CONFIGURATION--
SECURELY)
BALL
FIGURE 5B.
FIGURE 5A.
PLATE HOOK
FORM NO. 40987-01
PAGE 3
NOTE:
STEP 6:
CAUTION:
THE SPLICES SHOULD BE TURNED UPWARD AND PUSHED CAREFULLY UP INTO THE OUTLET BOX.
OTHER SIDE OF THE BOX.
GREEN WIRES ON ONE SIDE OF THE OUTLET BOX, AND THE BLACK AND BLACK/WHITE WIRES ON THE
B. AFTER MAKING THE WIRE CONNECTIONS, THE WIRES SHOULD BE SPREAD APART WITH THE WHITE AND
NO BARE WIRE OR WIRE STRANDS SHOULD BE VISIBLE AFTER MAKING CONNECTIONS.
GENERAL-USE SWITCH.
STRIPE TO THE WALL SWITCH LEAD. THE WALL SWITCH MUST BE ACCEPTABLE FOR USE AS A
IF A SEPARATE WALL SWITCH WILL BE USED TO CONTROL THE LIGHT, CONNECT THE BLACK WIRE WITH WHITE
CONNECT THE GROUND WIRE TO THE GREEN LEADS FROM THE MOTOR AND CEILING PLATE.  SEE FIGURE 6.
STRIPE MOTOR LEAD (SEE NOTE). CONNECT THE WHITE ELECTRICAL SUPPLY LEAD TO THE WHITE MOTOR LEAD.
CONNECT BLACK ELECTRICAL SUPPLY LEAD TO THE BLACK MOTOR LEAD AND THE BLACK WITH WHITE
A. CONNECT ELECTRICAL SUPPLY LEADS TO THE LEADS FROM MOTOR, USING APPROVED CONNECTORS.
FINAL WIRING
CAUTION:
STEP 7:
FAILURE TO SECURELY ASSEMBLY THE CANOPY SCREWS COULD RESULT IN THE FAN FALLING.
(3) SCREWS SECURELY.
ROTATE FAN COUNTERCLOCKWISE UNTIL ALL (3) MOUNTING SCREWS DROP INTO SLOT RECESSES. TIGHTEN
PLATE. LIFT FAN UNTIL CEILING PLATE MOUNTING SCREWS (3) ARE SEATED IN BOTTOM OF SLOTS IN CANOPY.
B. POSITION (3) SLOTS IN CANOPY DIRECTLY UNDER AND IN LINE WITH (3) MOUNTING SCREWS IN CEILING
THE CANOPY HAS (3) MATING SLOTS. SEE FIGURE 7.
REMOVE THE FAN FROM THE CEILING PLATE HOOK. MAKE SURE NOT TO BREAK ANY WIRE CONNECTIONS.
PHILLIPS ROUND HEAD SCREWS HALFWAY INTO THESE HOLES. SEE FIGURE 7.
A. THE CEILING PLATE HAS (3) MOUNTING SCREW HOLES LOCATED ON THE SIDE. INSTALL (3) #10-32 X 1/2"
FINISH FAN ASSEMBLY
ENGAGES TAB IN CANOPY
ROTATE BALL UNTIL GROOVE IN BALL
LEAD WIRES
GROOVE IN BALL
PIPE NIPPLE
CANOPY
FIGURE 7A.
CEILING PLATE
GREEN GROUND WIRE
FIGURE 6.
CEILING
CEILING PLATE
GROUND WIRE
CANOPY
ADAPTOR
FAN ASSEMBLY
LOCTITE ON THREADS
LOCKWASHERS AND
SCREWS WITH
SCREW HOLE
SCREW HEAD
CANOPY
FIGURE 5.
SETSCREW (TIGHTEN
PIPE NIPPLE
CANOPY
MOTOR
PIPE NIPPLE
PIPE NIPPLE
LEAD WIRES
6" MIN