Chapter 14: System Maintenance 
 
 
235
 
 
Restarting CC-SG after Shutdown 
After shutting down CC-SG, use one of these two methods to restart the 
unit: 
 
Use the Diagnostic Console. See 
Restart CC-SG with Diagnostic 
Console
 (on page 315)
 
Recycle the power to your CC-SG unit. 
 
Powering Down CC-SG 
If CC-SG loses AC power while it is up and running, it will remember the 
last power state. Once AC power is restored, CC-SG automatically 
reboots. However, if CC-SG loses AC power when it is powered off, it will 
remain powered off when AC power is restored. 
Important: Do not hold the POWER button to forcibly power down 
CC-SG. The recommended way to power down CC-SG is to use the 
Diagnostic Console's "CC-SG System Power OFF" command. See 
Power Off CC-SG System from Diagnostic Console (on page 317)
 
To power down the CC-SG: 
1.  Remove the bezel and firmly tap the POWER button. 
2.  Wait approximately one minute while CC-SG gracefully powers 
down. 
Note: Users logged into CC-SG via Diagnostic Console will receive a 
short broadcast message when the CC-SG unit is powered down. 
Users logged into CC-SG via a web browser or SSH will not receive 
a message when the CC-SG unit is powered down. 
3.  If you must remove the AC power cord, let the power down process 
finish completely before removing the power cord. This is required 
for CC-SG to complete all transactions, close the databases, and 
place the disk drives into a safe state for power removal. 
 
Ending CC-SG Session 
There are two ways to end a CC-SG Session. 
 
Log out to end your session while keeping the client window open. 
See 
Log Out of CC-SG
 (on page 235)
 
Exit to end your session and close the client window. See 
Exit 
CC-SG
 (on page 236)
 
Log Out of CC-SG 
1.  Choose Secure Gateway > Logout. The Logout window opens.