J-300
11.6 
Programming the CLEARRAY Bulb Replacement Timer
To make changes to the CLEAR
RAY bulb replacement timer or to reset 
it, follow the steps below (Figure 7).
A.  Press the 
Menu ( 
 ) button three times to display the CLEAR
RAY 
Bulb Replacement Timer Menu. The LED screen will display “U.”
B.  Press the 
Warmer (   ) button to enter the menu. The LED screen 
will display the number of days remaining or zero.
Note: If you press the Warmer (   ) button after the number of days 
remaining you will revert back to the “U” menu. You will need to repeat 
step B to re-enter the menu.
C.  Press the 
Jets Pump 1 ( 
 ) button to access the CLEAR
RAY bulb 
replacement timer. The display on the LED screen will blink once to 
indicate that the system is ready to accept changes.
D.  Pressing the 
Warmer (   ) or Cooler (   ) button will add or 
subtract days in increments of 10 days except when 360 is reached. 
Then a 5-day increment occurs. The range for programming is from 0 
to 365 days.
E.  Once you select the number of days, press the 
Jets Pump 1 ( 
 )
button to confirm the selection. The display of the LED screen will 
blink twice to indicate that the changes have been accepted. You 
must press the 
Jets Pump 1 ( 
 ) button to confirm your selection 
or the current settings will remain active.
Note: If no button is pressed within 5 seconds of each selection the 
screen will revert back to the Main Menu and the current settings will 
remain active.
11.7 
Economy Menu
In Economy mode, the heater 
only activates after a Secondary Filtration 
cycle has finished. The heater will run for a maximum of 30 minutes. 
The heater can turn off prior to the 30 minutes if the programmed 
water temperature is reached. The Secondary Filtration program 
determines the number of cycles (from 1 to 4) that the heater will be 
allowed to activate. For example, if you have programmed the SF3 
setting (10 minutes of filtration every 6 hours), then the heater will run, 
for a maximum of 30 minutes, after the end of each of the 10-minute 
secondary filtration cycle, for up to four times per day. Reference the 
chart that follows.
Will return to 
the “U” menu
Blinks once
Blinks twice
Activates 
submenu for 
changes
Adds days in 
10-day incre-
ments
OR
OR
Substracts days 
in 10-day incre-
ments
PRESS
PRESS
PRESS
PRESS
Figure 7