Specific electrical requirements are listed in the chart below. 
Follow the requirements for the type of plug on the power supply 
cord.
Recommended ground method
This air conditioner must be grounded. This air conditioner is 
equipped with a power supply cord having a grounded 3 prong 
plug. To minimize possible shock hazard, the cord must be 
plugged into a mating, grounded 3 prong outlet, grounded in 
accordance with all local codes and ordinances. If a mating outlet 
is not available, it is the customer's responsibility to have a 
properly grounded 3 prong outlet installed by a qualified electrical 
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 - 
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
Power Supply Cord
NOTE: Your unit’s device may differ from the one shown.
This room air conditioner is equipped with a power supply cord 
required by UL. This power supply cord contains state-of-the-art 
electronics that sense leakage current. If the cord is crushed, the 
electronics detect leakage current and power will be 
disconnected in a fraction of a second. 
To test your power supply cord: 
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET.
3. Press TEST (listen for click; Reset button will trip and pop 
out).
4. Press and release RESET (listen for click; Reset button will 
latch and remain in). The power supply cord 
 
is ready for 
operation.
NOTES:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when 
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The 
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new 
power supply cord obtained from the product manufacturer 
and must not be repaired. 
The power supply cord contains no user serviceable parts. 
Opening the tamper-resistant case voids all warranty and 
performance claims.
Power supply cord 
Wiring requirements
115 volt (103.5 min. - 
126.5 max.)
0-7.5 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
115 volt (103.5 min. - 
126.5 max.)
7.6-12 amps
15-amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
230/208 volt (197.6 min. - 
253 max.)
0-12 amps
15 amp time-delay fuse or 
circuit breaker
Use on single outlet circuit only.
¹⁄₄
"
(0.6 cm)
A. Reset button
B. Test button
TEST
RESET
A
B
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.