Delta Tau GEO BRICK DRIVE Manuel D’Utilisation

Page de 294
 Geo Brick Drive User Manual 
Motor Setup 
 169 
Resolver 
With resolvers, it is recommended to use the unfiltered data processed in the Encoder Conversion Table: 
// these addresses can differ depending on the encoder conversion table management 
I183=$3503 
; Motor 1 On-going Commutation Position Address 
I283=$350B 
; Motor 2 On-going Commutation Position Address 
I383=$3513 
; Motor 3 On-going Commutation Position Address 
I483=$351B 
; Motor 4 On-going Commutation Position Address 
I583=$3523 
; Motor 5 On-going Commutation Position Address 
I683=$352B 
; Motor 6 On-going Commutation Position Address 
I783=$3533 
; Motor 7 On-going Commutation Position Address 
I883=$353B 
; Motor 8 On-going Commutation Position Address 
 
I101,8,100=1 
; Motors 1-8 Commutation Enabled, from X-register 
 
Yaskawa 
With Yaskawa feedback devices, it is recommended to use the processed data in the Encoder Conversion 
Table (same as position): 
I183=I104 
; Motor 1 On-going Commutation Position Address 
I283=I204 
; Motor 2 On-going Commutation Position Address 
I383=I304 
; Motor 3 On-going Commutation Position Address 
I483=I404 
; Motor 4 On-going Commutation Position Address 
I583=I504 
; Motor 5 On-going Commutation Position Address 
I683=I604 
; Motor 6 On-going Commutation Position Address 
I783=I704 
; Motor 7 On-going Commutation Position Address 
I883=I804 
; Motor 8 On-going Commutation Position Address 
 
I101,8,100=1 
; Motors 1-8 Commutation Enabled, from X-register