Chapter 1
 
GPIB Command Dictionary
CDANalyzer subsystem
:PNINcrement <real number>
:PNINcrement?
These commands set/query the PN increment. If you know the PN 
incrment, enter it with this command to speed the PN offset search. If 
you do not know the increment, enter a 1. 
This command utilizes the :INCR command of the “Real Number 
Setting Syntax” on page 299.
Syntax
CDAN:PNIN <real number>!values from 1 to 256
CDAN:PNIN? 
!returns the value of the PN increment
Screen/field equivalent
CDAN:PNIN controls the 
PN Incrment
 field on the CODE DOM screen 
when the CDMA standard is set to “IS-95 Only”. This field is displayed 
only when the 
Find PN
 field on the 
PN Setup
 menu is set to 
Auto
.
:PNMode <string>
:PNMode?
These commands set/query the PN offset mode. 
• ‘Auto’ is used to calculate the system’s PN offset if it is unknown. 
When ‘Auto’ is selected, the CDAN:PNIN command can be used to 
enter a PN increment and speed the PN offset calculation.
• ‘Manual’ is used to enter a known PN offset. When ‘Manual’ is 
selected, the PN offset is entered using the CDAN:PNOF command.
Syntax
CDAN:PNM ‘Auto’
         ‘Manual’
CDAN:PNM? !returns the PN Offset mode
Screen/field equivalent
CDAN:PNM controls the 
Find PN
 field on the 
PN Setup
 menu of the 