Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
Chapter 1
229
GPIB Command Dictionary
MEASure subsystem
:CDANalyzer:MARKer:LEVel <meas cmnd>
:CDANalyzer:MARKer:LEVel?
IS-95 Only mode. These commands set/query the level at the marker on 
the code domain analyzer’s trace during power or fast power 
measurements (see :CDAN:MEAS on page  124). This measurement is 
made relative to the value at Walsh Code 0.
This measurement utilizes the Number Measurement Syntax, but does 
not use the :METer command.
Syntax
MEAS:CDAN:MARK:LEV <meas cmd> 
MEAS:CDAN:MARK:LEV?
Example
MEAS:CDAN:MARK:LEV? 
Screen/field equivalent
MEAS:CDAN:MARK:LEV? reads the 
Lvl
 field on the 
Marker
 menu of 
the CODE DOM screen when a power or fast power measurement is 
selected, and the 
Ch pwr unit
 field on the 
CD Setup
 menu is set to 
Rel
This applies when the CDMA standard is set to “IS-95 Only”.