Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
260
Chapter 1
 
GPIB Command Dictionary
MEASure subsystem
:DEC:AMPS|TACS:CDATa?
This command queries the decoded data for the control channel. 
Syntax
MEAS:DEC:AMPS:CDAT?
Example
MEAS:DEC:AMPS:CDAT? !returns a quoted string reporting the 
decoded data obtained from the control channel measured by 
the signaling unit. 
For example, the Signaling Decoder reads the control channel 
and returns the data as shown:
09A15386CDA286604938B128063FD5F8
030078ECDBED872DABF0D308A1718FDB
685461FC0C2130410982E2DAE08C0300
54D0D9B450C08231AFD909BED8C840C0
The information received is the same as that displayed in the 
Data (hex) field of the SIGNALING DECODER screen.
Screen/field equivalent
MEAS:DEC:AMPS:CDAT? reads the 
Data (hex)
 measurement field on 
the SIGNALING DECODER screen when the 
Mode
 field is set to 
AMPS-TACS
, and the 
Channel
 field is set to 
Cntl
.