Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
Chapter 1
261
GPIB Command Dictionary
MEASure subsystem
:DEC:AMPS|TACS:DATA?
This command queries the decoded data for the voice channel.
Syntax
MEAS:DEC:AMPS:DATA?
Example
MEAS:DEC:AMPS:DATA? !returns a quoted string reporting the 
decoded data obtained from the voice channel measured by the 
signaling unit.
For example, the Signaling Decoder reads the voice channel 
and returns the data as depicted below:
09A15386CDA286604938B128063FD5F8
030078ECDBED872DABF0D308A1718FDB
685461FC0C2130410982E2DAE08C0300
54D0D9B450C08231AFD909BED8C840C0
The information received is the same as that displayed in the 
Data (hex)
 field of the SIGNALING DECODER screen.
Screen/field equivalent
MEAS:DEC:AMPS:DATA? reads the 
Data (hex)
 measurement field on 
the SIGNALING DECODER screen when the 
Mode
 field is set to 
AMPS-TACS
, and the 
Channel
 field is set to 
Voice
.
:DEC:DTMF:LOW:FREQuency:ABSolute <meas cmnd>
:DEC:DTMF:LOW:FREQuency:ABSolute?
These command set/query the frequency of the low tone in the DTMF 
pair. The MEAS:DEC:DTMF:LOW:FREQ:DISP ‘Freq’ command must 
be used to display the absolute frequency of the low tone.
Syntax
MEAS:DEC:DTMF:LOW:FREQ:ABS 
MEAS:DEC:DTMF:LOW:FREQ:ABS? !returns up to 20 real values
Screen/field equivalent
MEAS:DEC:DTMF:LOW:FREQ:ABS? reads the 
Lo Tone
 column on the 
SIGNALING DECODER screen. The 
Mode
 field must be set to 
DTMF
 and 
the upper subfield of the 
Lo Tone
 field must be set to 
Freq