Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
Chapter 1
91
GPIB Command Dictionary
AFG2|ENCoder subsystem
:NAMPs|NTACs:DSAT:STOP
This command stops the DSAT if it is being sent. See 
“:NAMPs|NTACs:DSAT:SEND <string> 
:NAMPs|NTACs:DSAT:SEND?” on page  90.
Syntax
AFG2:NAMP:DSAT:STOP
Screen/Field Equivalent
AFG2:NAMP:DSAT:STOP controls the 
Stop DSAT
 field on the 
SIGNALING ENCODER screen when the 
Mode
 field is set to 
NAMP-NTAC
, and the 
Channel
 field is set to 
Voice
.
:NAMPs|NTACs[:FOCC]:AM <real number>
:NAMPs|NTACs[:FOCC]:AM?
This command sets/queries the data level when the AFG2:DEST ‘AM’ 
command is used. The data level units are %. 
Syntax
AFG2:NAMP:FOCC:AM 
AFG2:NAMP:FOCC:AM?
Screen/field equivalent
AFG2:NAMP[:FOCC]:AM controls the 
Data Level
 field when 
AFGen2 
To
 field is set to 
AM
 on the SIGNALING ENCODER screen when the 
Mode
 field is set to 
NAMP-NTAC
, and the 
Channel
 field is set to 
Cntl
.