Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
Chapter 1
93
GPIB Command Dictionary
AFG2|ENCoder subsystem
:NAMPs|NTACs[:FOCC]:RATE <real number>
:NAMPs|NTACs[:FOCC]:RATE?
These commands set/query the data rate of the encoded message. 
This command utilizes the “Real Number Setting Syntax” on page  299 
but does not use the :STATe command.
Syntax
AFG2:NAMP:FOCC:RATE
AFG2:NAMP:FOCC:RATE?
Screen/field equivalent
AFG2:NAMP[:FOCC]:RATE controls the 
Data Rate 
field on the 
SIGNALING ENCODER screen when the 
Mode
 field is set to 
NAMP-NTAC
, and the 
Channel
 field is set to 
Cntl
.
:NAMPs|NTACs[:FOCC]:FILLer:DATA1 <string>
:NAMPs|NTACs[:FOCC]:FILLer:DATA2 <string>
:NAMPs|NTACs[:FOCC]:FILLer:DATA1?
:NAMPs|NTACs[:FOCC]:FILLer:DATA2?
These commands set/query FOCC filler data. Each filler contains 7 
hexadecimal characters representing the 2 type bits and 26 information 
bits of the control filler/message word. The control filler is sent 
continuously when the :NAMPs|NTACs[:FOCC]:FILL:SEND command 
is used or after a control message has been sent using 
:NAMPs|NTACs:SEND. 
Both filler fields must be full (seven digits) for the forward control 
channel information to be structured correctly. Do not leave any blank 
spaces.
To use this command, AFG2:NAMP:CHAN must be set to ‘Cntl’.
Syntax
AFG2:NAMP[:FOCC]:FILL:DATA1 <string>
AFG2:NAMP[:FOCC]:FILL:DATA2 <string>
AFG2:NAMP[:FOCC]:FILL:DATA1?
AFG2:NAMP[:FOCC]:FILL:DATA2?
Screen/field equivalent
AFG2:NAMP[:FOCC]:FILL:DATA1 and DATA 2 control the 
Filler
 
fields for Stream A and Stream B on the SIGNALING ENCODER 
screen when the 
Mode
 field is set to 
NAMP-NTAC
, and the 
Channel
 field is 
set to 
Cntl
.