GPIB Command Dictionary
AFG2|ENCoder subsystem
:NAMPS|NTACS[:FOCC]:MESSage:DATA1 <string>
:NAMPS|NTACS[:FOCC]:MESSage:DATA2 <string>
:NAMPS|NTACS[:FOCC]:MESSage:DATA1?
:NAMPS|NTACS[:FOCC]:MESSage:DATA2?
These commands set/query FOCC Stream A and Stream B message 
data. Like the filler data, the message information can only be input in 
full (seven digit) lines. Also, message streams A and B must have the 
same number of lines in them. 
To use this command, AFG2:NAMP:CHAN must be set to ‘Cntl’.
Syntax
AFG2:NAMP[:FOCC]:MESS:DATA1 <string>
AFG2:NAMP[:FOCC]:MESS:DATA2 <string>
AFG2:NAMP[:FOCC]:MESS:DATA1?
AFG2:NAMP[:FOCC]:MESS:DATA2?
Screen/field equivalent
AFG2:NAMP:MESS controls the 
Message
 fields for FOCC Stream A 
and Stream B on the SIGNALING ENCODER screen when the 
Mode
 
field is set to 
NAMP-NTAC
. These fields are displayed only when the 
Channel
 field is set to 
Cntl
.
:NAMPs|NTACs:FVC:MESS <string>
:NAMPs|NTACs:FVC:MESS?
These commands set/query the seven hexadecimal characters (28 bits) 
of the FVC message. These 7 characters are combined with 12 parity 
bits calculated by the encoder to output a 40-character data stream. 
This data is output when the AFG2:NAMP:FVC:SEND ‘Message’ 
command is sent.
The entire field must contain data. No blank spaces are allowed. The 
DSAT is turned off while the FVC message stream is sent.
Syntax
AFG2:NAMP:FVC:MESS <string>
AFG2:NAMP:FVC:MESS?
Screen/field equivalent
AFG2:NAMP:FVC:MESS controls the FVC 
Message
 field on the 
SIGNALING ENCODER screen when the 
Mode
 field is set to 
NAMP-NTAC
, and the 
Channel
 field is set to 
Voice
.