Agilent Technologies E6380-90073 Manuale Utente
96
Chapter 1
GPIB Command Dictionary
AFG2|ENCoder subsystem
:NAMPs|NTACs:FVC:RATE <real number>
:NAMPs|NTACs:FVC:RATE?
:NAMPs|NTACs:FVC:RATE?
These commands set/query the data rate of the encoded message.
This command utilizes the “Real Number Setting Syntax” on page 299
but does not use the :STATe command.
but does not use the :STATe command.
Syntax
AFG2:NAMP:FVC:RATE <real number>
AFG2:NAMP:FVC:RATE?
Screen/field equivalent
AFG2:NAMP:FVC:RATE controls the
Data Rate
field on the
SIGNALING ENCODER screen when the
Mode
field is set to
NAMP-NTAC
, and the
Channel
field is set to
Voice
.
:NAMPs|NTACs:FVC:AM <real number>
:NAMPs|NTACs:FVC:AM?
:NAMPs|NTACs:FVC:AM?
This command sets/queries the data level when the AFG2:DEST ‘AM’
command is used. The data level units are %.
command is used. The data level units are %.
This command utilizes the “Real Number Setting Syntax” on page 299.
Syntax
AFG2:NAMP:FVC:AM
AFG2:NAMP:FVC:AM?
Screen/field equivalent
AFG2:NAMP:FVC:AM controls the
Data Level
field when
AFGen2 To
field is set to
AM
on the SIGNALING ENCODER screen when the
Mode
field is set to
NAMP-NTAC
, and the
Channel
field is set to
Voice
.