GPIB Command Dictionary
AFG2|ENCoder subsystem
:NAMPs|NTACs:FVC:FM <real number>
:NAMPs|NTACs:FVC:FM?
This command sets/queries the data level when the AFG2:DEST ‘FM’ 
command is used. The data level units are kHz. 
Syntax
AFG2:NAMP:FVC:FM 
AFG2:NAMP:FVC:FM?
Screen/field equivalent
AFG2:NAMP:FVC:FM controls the 
Data Level
 field when 
AFGen2 To
 
field is set to 
FM
 on the SIGNALING ENCODER screen when the 
Mode
 
field is set to 
NAMP-NTAC
, and the 
Channel
 field is set to 
Voice
.
:NAMPs|NTACs:FVC:LEVel <real number>
:NAMPs|NTACs:FVC:LEVel?
These commands set/query the data level when the AFG2:DEST ‘Audio 
Out’ command is used. The data level units are mV. 
Syntax
AFG2:NAMP:FVC:LEV 
AFG2:NAMP:FVC:LEV?
Screen/field equivalent
AFG2:NAMP:FVC:LEV controls the 
Data Level
 field when 
AFGen2 To
 
field is set to 
Audio Out
 on the SIGNALING ENCODER screen when 
the 
Mode
 field is set to 
NAMP-NTAC
, and the 
Channel
 field is set to 
Voice
.