Operation
 
 
Master Key switch On Main Control Unit
 
The  master  key  switch  is  located  on  the  Main  Control  Unit.   The  master  key switch  allows 
you to completely disable the alarm system, and is used primarily for transportation purposes 
so as not to flatten the internal back-up battery unnecessarily. Leaving the switch on without 
main power connected will cause long-term damage to the battery cells.  
 
To  utilise  your  Watchguard  Digital,  turn  the  key  switch  to  the  ‘ON’  position.    Two keys are 
provided with the kit, and it is suggested you keep them on each key ring with your remote 
controls. When you switch on the system, the LED on the Main Control Unit will flash once 
every 5 seconds to indicate that the unit is active.    
 
When unit is turned on for the first time it will automatically enter Walk test mode  - unless 
the cover is on - which will allow you to test that each device had good signal coverage. To 
exit walk test mode Arm/Disarm the alarm or wait 20 minutes and it will exit automatically.
 
 
 
Key switch Located 
(On the Main Control Unit)
 
 
 
Exit & Entry Delays 
 
Your Watchguard Digital is equipped with Entry and Exit Delay Warning capabilities.  
 
Exit Delay
 is a 30 second delay before the alarm is actually armed; this delay is to provide 
the user with sufficient time to exit the premises.  During the Exit Delay the internal screamer 
of the alarm will chirp at 1-second intervals. 
 
Entry Delay (For Use With The Optional Wireless Keypad) 
 
The programmable Entry Delay is 30 seconds. The purpose of this function is to allow users 
to  disarm  the  alarm  system  within  the  delay  before  the  alarm  is  set-off  (triggering  the 
Screamer,  Siren/  Strobe  and  communicating  with  the  DIGITAL  MONITORING  CENTRE).  
The Entry Delay is turned off as standard. For it to be functional, the wireless alarm zones 
you would like an entry delay on must be programmed via the optional Wireless Keypad. For 
information  on  how  to  program  Entry  Delay  on  a  particular  zone  please  refer  to  the  zone 
programming section of this manual on page 44. 
 
Red LED Indicator Main Control Unit 
 
The red LED indicator is located on the bottom right corner of the main control unit. 
This indicator will flash to indicate the current status of the system: 
 
Flashing once every second 
Armed 
Flashing once every 2 secs 
Home/Armed 
Flashing Once Every 5 Secs  
Disarmed 
On Steady   
 
 
Exit Delay In Progress 
Fast Flashing 
 
 
System Is In Program Mode 
Blinking Off Every 5 Seconds 
Power On Walk Test Mode