Fixture Linking 
You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures 
the data link can support.  
Important:  
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-
485 standard no more than 32 fixtures should be connected on one data link. Connecting 
more than 32 fixtures on one serial data link without the use of a DMX optically-isolated 
splitter may result in deterioration of the digital DMX signal.  
Maximum recommended serial data link distance: 500 m (1640 ft) 
Maximum recommended number of fixtures on a serial data link: 32 
Data Cabling 
To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX 
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own 
cable please use data-grade cables that can carry a high quality signal and are less prone to 
electromagnetic interference. 
DMX Data Cable 
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. 
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must 
have the following characteristics: 
Type: 
shielded, 2-conductor twisted pair 
Maximum capacitance between conductors: 
30 pF/ft 
Maximum capacitance between conductor and shield: 
55 pF/ft 
Maximum resistance: 
20 ohms/1000 ft 
Nominal impedance: 