Chauvet 550 Manuale Utente

Pagina di 26
Legend™ 550 Spot User Manual 
13 
1/11/2010 11:36 AM
 
COMMON 
DMX + 
DMX
 - 
INPUT 
OUTPUT 
1 
3 
2 
1 
3 
2 
1 
3 
2 
Resistance 120 ohm 
¼ W between pin 2 
(DMX -) and pin 3 
(DMX +) on the output 
of the last fixture. 
To avoid signal transmission 
problems and interference, it is 
always advisable to connect a DMX 
signal terminator.
 
3-pin DMX connector configuration 
Resistance 120 ohm 
¼ W between pin 2 
(DMX -) and pin 3 
(DMX +) on the output 
of the last fixture. 
 
5-pin DMX connector configuration 
Cable Connectors 
Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 
 
Caution! 
Do not allow contact between the common and the fixture’s chassis ground. Grounding the 
common can cause a ground loop, and your fixture may perform erratically. Test cables with 
an ohmmeter to verify correct polarity and to make sure the pins are not grounded or shorted 
to the shield or each other. 
 
3-Pin to 5-Pin Conversion Chart 
Note! 
If you use a controller with a 5-pin DMX output connector, you will need to use a 5-pin to 3-pin 
adapter. CHAUVET Model No: DMX5M, or DMX5F.The chart below details a proper cable 
conversion: 
3-P
IN TO 
5-P
IN 
C
ONVERSION 
C
HART
 
Conductor 
3-Pin Female (Output) 
5-Pin Male (Input) 
Ground/Shield 
Pin 1 
Pin 1 
Data ( - ) signal 
Pin 2 
Pin 2 
Data ( + ) signal 
Pin 3 
Pin 3 
Not used 
 
Pin 4 
Not used 
 
Pin 5