Enterasys Networks 2G4082-25 ユーザーズマニュアル
COM Port Pinout Assignments
A-2 Specifications
COM Port Pinout Assignments
The COM port is a serial communications port for local access to Local Management. Refer to
Regulatory Compliance
The 2G4082‐25 meets the safety and electromagnetic compatibility (EMC) requirements listed in
Environmental
Operating Temperature
5°C to 40°C (41°F to 104°F)
Storage Temperature
-30°C to 73°C (-22°F to 164°F)
Operating Relative Humidity
5% to 90% (non-condensing)
Table A-1 Specifications for 2G4082-25 (continued)
Item
Specification
Table A-2 COM Port Pin Assignments
Pin
Signal Name
Input/Output
1
Transmit Data (XMT)
Output
2
Clear to Send (CTS)
Input
3
Data Set Ready (DSR)
Input
4
Receive Data (RCV)
Input
5
Signal Ground (GND)
NA
6
Request to Send (RTS)
Output
7
Data Terminal Ready (DTR)
Output
8
Data Carrier Detect (DCD)
Input
Table A-3 Compliance Standards
Regulatory Compliance
Standards
Safety
UL 60950, CSA C22.2 No. 60950, 2006/95/EC, EN 60950, IEC
60950, EN 60825, 21 CFR 1040.10.
60950, EN 60825, 21 CFR 1040.10.
Electromagnetic Compatibility (EMC)
47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN 55022,
EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS CISPR 22,
VCCI V-3.
EN 61000-3-2, EN 61000-3-3, EN 55024, AS/NZS CISPR 22,
VCCI V-3.