 5-19. 
TREBLE Gain Data 
Function 
The external control equipment changes the TREBLE gain data of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  7FH  03H  DATA00  DATA01  DATA0  CKS 
 
DATA00: USER PICTURE Gain Flag     
05H 
 
DATA01: TREBLE Gain Flag   
 
04H 
 
DATA02: TREBLE Gain   
 
F3H: -13 
  
 
 
  
FFH: 
-01 
  
00H: 
  
01H: 
+01 
  
 
  
0DH: 
+13 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
05H 
 
DATA01: TREBLE Gain Flag   
 
04H 
 
 5-20. 
BALANCE Gain Data   
Function 
The external control equipment changes the BALANCE gain data of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER PICTURE Gain Flag     
05H 
 
DATA01: BALANCE Gain Flag   
 
02H 
 
DATA02: BALANCE Gain   
 
EAH: -22 
  
 
 
  
FFH: 
-01 
  
00H: 
  
01H: 
+01 
  
 
  
16H: 
+22 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
05H 
 
DATA01: BALANCE Gain Flag   
 
02H