RS-232C Control Specification Page: 17 / 49
Document Version [1.0]
Company Restricted
5-21.
SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H 60H 51H 01H DATA00 CKS
DATA00 02H: STADIUM
03H:
ZOOM
04H:
NORMAL
05H:
ANAMORHIC
(FULL)
06H:
REAL
08H:
UNDERSCAN
09H:
14:9
0AH:
2.35:1
ACK
7FH 60H 80H 51H 01H DATA00 CKS
DATA00 02H: STADIUM
03H:
ZOOM
04H:
NORMAL
05H:
ANAMORHIC(FULL)
06H:
REAL
08H:
UNDERSCAN
09H:
14:9
0AH:
2.35:1
*If it selects DATA00 “08: UNDERSCAN”, it need to set No.78 UNDERSCAN setting ON.
5-22.
V. POSITION Gain Data
Function
The external control equipment changes the V. POSITION gain data of the plasma monitor.
Transmission Data
The external control equipment changes the V. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V.POSITION Gain Flag
01H
DATA02: V.POSITION Gain
C0H: -64
:
FFH:
-01
00H:
0
01H:
+01
:
40H:
+64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V.POSITION Gain Flag
01H