Marantz PD4201 ユーザーズマニュアル

ページ / 49
  PDxx01  
       RS-232C Control Specification                                                      Page: 18 / 49 
Document Version [1.0]
 
Company Restricted 
 
 
 5-23. 
H. POSITION Gain Data 
Function 
The external control equipment changes the H. POSITION gain data of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER PICTURE Gain Flag     
03H 
 
DATA01: H.POSITION Gain Flag   
 
02H 
 
DATA02: H.POSITION Gain   
 
80H: -128 
  
 
 
  
FFH: 
-01 
  
00H: 
  
01H: 
+01 
  
 
  
7FH: 
+127 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
03H 
 
DATA01: H.POSITION Gain Flag   
 
  02H 
 
 5-24. 
V. HEIGHT Gain Data   
Function 
The external control equipment changes the V-HEIGHT gain data of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER PICTURE Gain Flag   
03H 
 
DATA01: V-HEIGHT Gain Flag   
 
07H 
 
DATA02: V-HEIGHT Gain   
 
00H: 0 
  
 
  
40H: 
+64 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
03H 
 
DATA01: V-HEIGHT Gain Flag      
 
  07H 
 
 5-25. 
H. WIDTH Gain Data   
Function 
The external control equipment changes the H-WIDTH gain data of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER PICTURE Gain Flag     
03H 
 
DATA01: H-WIDTH Gain Flag   
 
08H 
 
DATA02: H-WIDTH Gain   
 
00H: 0 
  
 
  
40H: 
+64 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
03H 
 
DATA01: H-WIDTH Gain Flag       
 
  08H