Netgear FS728TS - ProSAFE 24 Port 10/100 Stackable Smart Switch with 4 Gigabit Ports インストールガイド

ページ / 190
FS700TS Smart Switch Software Administration Manual
3-12
Managing System Settings
v1.0, September 2007
Inserting a Stacking Member
When a stacking member is inserted into a running stack, it is automatically assigned a unit 
number. Note that a unit should not be powered up until it has been connected to the stack. If the 
user has already configured a Unit ID for the newly joined unit, a new Unit ID is not assigned.
Exchanging Stacking Members
If a stack member with the same Unit ID replaces an existing Unit ID with the same Unit ID, the 
previous device configuration is applied to the inserted stack member. If the new inserted device 
has either more than or less ports than the previous device, the relevant port configuration is 
applied to the new stack member. 
Switching the Stacking Master
The Secondary Master replaces the Stacking Master if one of the following events occur: 
The Stacking Master fails or is removed from the stack.
Links from the Stacking Master to the stacking members fails.
A soft switchover is performed via the web interface. 
Switching between the Stacking Master and the Secondary Master results in a limited service loss. 
Any dynamic tables are relearned if a failure occurs. The running configuration file is 
synchronized between Stacking Master and the Secondary Master and continues running on the 
Secondary Master.
Stack Configuration and Management
The Stacking menu contains the following options:
Basic
The Stacking Basic menu contains the following option: