KitchenAid KRMF706EBS 使用とお手入れ

ページ / 120
12
12
NOTE: This refrigerator is intended for use in a location where the 
temperature ranges from a minimum of 55°F (13°C) to a maximum of 
110°F (43°C). The preferred room temperature range for optimum 
performance, which reduces electricity usage and provides superior 
cooling, is between 60°F (15°C) and 90°F (32°C). It is recommended 
that you do not install the refrigerator near a heat source, such as an 
oven or radiator.
Electrical Requirements
Before you move your refrigerator into its final location, it is important 
to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 volt, 60 Hz, AC only 15- or 20-amp fused, grounded electrical 
supply is required. It is recommended that a separate circuit serving 
only your refrigerator and approved accessories be provided. Use an 
outlet that cannot be turned off by a switch. Do not use an 
extension cord.
NOTE: Before performing any type of installation, cleaning, or 
removing a light bulb, turn OFF Cooling, and then disconnect the 
refrigerator from the electrical source. When you have finished, 
reconnect the refrigerator to the electrical source and turn ON Cooling. 
See “Using the Control(s).”
Water Supply Requirements 
A cold water supply with water pressure between 35 and 120 psi 
(241 and 827 kPa) is required to operate the water dispenser and ice 
maker. If you have questions about your water pressure, call a 
licensed, qualified plumber.
NOTE: If the water pressure is less than what is required, the flow of 
water from the water dispenser could decrease or ice cubes could be 
hollow or irregular shaped.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the 
refrigerator needs to be between 35 and 120 psi (241 and 827 kPa).
If a reverse osmosis water filtration system is connected to your cold 
water supply, the water pressure to the reverse osmosis system needs 
to be a minimum of 40 to 60 psi (276 to 414 kPa).
Check to see whether the sediment filter in the reverse osmosis 
system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill after 
heavy use. The tank capacity could be too small to keep up with 
the requirements of the refrigerator. 
NOTE: Faucet-mounted reverse osmosis systems are not 
recommended.
If your refrigerator has a water filter, it may further reduce the water 
pressure when used in conjunction with a reverse osmosis system. 
Remove the water filter. See “Water Filtration System.”
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Connect the Water Supply
Read all directions before you begin.
IMPORTANT:
Plumbing shall be installed in accordance with the International 
Plumbing Code and any local codes and ordinances.
The gray water tubing on the back of the refrigerator (which is used 
to connect to the household water line) is a PEX (cross-linked 
polyethylene) tube. Copper and PEX tubing connections from the 
household water line to the refrigerator are acceptable and will 
help avoid off-taste or odor in your ice or water. Check for leaks.
If PEX tubing is used instead of copper, we recommend the 
following Part Numbers: 
W10505928RP (7 ft [2.14 m] jacketed PEX), 
8212547RP (5 ft [1.52 m] PEX), or 
W10267701RP (25 ft [7.62 m] PEX). 
Install tubing only in areas where temperatures will remain above 
freezing.
Tools Needed:
Gather the required tools and parts before starting installation. 
Flat-blade screwdriver
⁷⁄₁₆" and ¹⁄₂" open-end wrenches or two adjustable wrenches
¹⁄₄" nut driver
NOTE: Do not use a piercing-type or 
³⁄₁₆" (4.76 mm) saddle valve which 
reduces water flow and clogs easier. 
Connect to Water Line
IMPORTANT: If you turn the refrigerator on before the water is 
connected, turn OFF the ice maker.
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long enough 
to clear line of water.
3. Use a quarter-turn shutoff valve or the equivalent, served by a 
¹⁄₂" 
household supply line. 
3³⁄₄
" (9.5 cm)
¹⁄₂
" (1.25 cm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING