Acceptance tests
If the system response is other than OK, see Software Input/Output
Reference — Administration 
(NN43001-611) to analyze the
messages.
5
End the session in LD 34:
****
6
Using a maintenance telephone, log into the system.
See "Communicating with the Meridian 1" in the Software
Input/Output Reference — Administration 
(NN43001-611) for details
on accessing the system using a maintenance telephone.
7
From the maintenance telephone, enter:
LD#34##
To test outpulsers and channels for the TDS loop, see
for a sample of the input commands used with
the maintenance telephone. See Software Input/Output Reference
— Administration 
(NN43001-611) for all tones that can be tested.
8
Exit LD 34 from the maintenance telephone:
****
—End—
Table 12
TDS tone tests
Input command
Dial pad
equivalent
Description
BSY#loop##
279#loop##
Provides busy tone from TDS loop specified.
C##
2##
Removes any active tone.
DIA#loop##
342#loop##
Provides dial tone from TDS loop specified.
OVF#loop##
683#loop##
Provides overflow tone from TDS loop specified.
RBK#loop##
725#loop##
Provides ringback tone from TDS loop specified.
RNG#loop##
764#loop##
Provides ring tone from TDS loop specified.
****
Exits TDS test program.