Siemens 6AV6651-7KA01-3AA4 - S7-1200 + KTP400 Basic Starter Kit 6AV6651-7KA01-3AA4 사용자 설명서
제품 코드
6AV6651-7KA01-3AA4
Motion control is easy
10.5 Motion control instructions
Easy Book
Manual, 03/2014, A5E02486774-AF
Manual, 03/2014, A5E02486774-AF
233
Note
Behavior with zero set velocity (Velocity = 0.0)
An MC_MoveVelocity task with "Velocity" = 0.0 (such as an MC_Halt task) aborts active
Behavior with zero set velocity (Velocity = 0.0)
An MC_MoveVelocity task with "Velocity" = 0.0 (such as an MC_Halt task) aborts active
motion tasks and stops the axis with the configured deceleration. When the axis comes to a
standstill, output parameter "InVelocity" indicates TRUE for at least one program cycle.
"Busy" indicates the value TRUE during the deceleration operation and changes to FALSE
"Busy" indicates the value TRUE during the deceleration operation and changes to FALSE
together with "InVelocity". If parameter "Execute" = TRUE is set, "InVelocity" and "Busy" are
latched.
When the MC_MoveVelocity task is started, status bit "SpeedCommand" is set in the
When the MC_MoveVelocity task is started, status bit "SpeedCommand" is set in the
technology object. Status bit "ConstantVelocity" is set upon axis standstill. Both bits are
adapted to the new situation when a new motion task is started.
10.5.9
MC_MoveJog (Move axis in jog mode) instruction
Table 10- 22 MC_MoveJog instruction
LAD / FBD
SCL
Description
"MC_MoveJog_DB"(
Axis:=_multi_fb_in_,
JogForward:=_bool_in_,
JogBackward:=_bool_in_,
Velocity:=_real_in_,
InVelocity=>_bool_out_,
Busy=>_bool_out_,
CommandAborted=>_bool_out_,
Error=>_bool_out_,
ErrorID=>_word_out_,
ErrorInfo=>_word_out_);
Use the MC_MoveJog instruction to move
the axis constantly at the specified
velocity in jog mode. This instruction is
typically used for testing and
commissioning purposes.
In order to use the MC_MoveJog
In order to use the MC_MoveJog
instruction, the axis must first be enabled.
1
STEP 7 automatically creates the DB when you insert the instruction.
2
In the SCL example, "MC_MoveJog_DB " is the name of the instance DB.
Table 10- 23 Parameters for the MC_MoveJog instruction
Parameter and type
Data type
Description
Axis
IN
TO_Axis_1
Axis technology object
JogForward
1
IN
Bool
As long as the parameter is TRUE, the axis moves in the positive
direction at the velocity specified in parameter "Velocity". The sign of
the value in parameter "Velocity" is ignored. (Default value: False)
JogBackward
1
IN
Bool
As long as the parameter is TRUE, the axis moves in the negative
direction at the velocity specified in parameter "Velocity". The sign of
the value in parameter "Velocity" is ignored. (Default value: False)